500X1000mm Small Composite Autoclave for Laboratory Use

Product Details
Customization: Available
Warranty: 2 Years
Effective Diameter: 500mm
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2013-01-17
Plant Area
3600 square meters
  • 500X1000mm Small Composite Autoclave for Laboratory Use
  • 500X1000mm Small Composite Autoclave for Laboratory Use
  • 500X1000mm Small Composite Autoclave for Laboratory Use
  • 500X1000mm Small Composite Autoclave for Laboratory Use
  • 500X1000mm Small Composite Autoclave for Laboratory Use
  • 500X1000mm Small Composite Autoclave for Laboratory Use
Find Similar Products

Basic Info.

Model NO.
SN-CGF0510
Working Length
1000mm
Design Pressure
1.2 MPa(12bar)
Design Temperature
250 ºC
Heating Mode
PLC+Him/PC
Certificate
Cpvqc/ASME/Ce/UL
Control Mode
PLC+Him/PC
Control Software
Tpc (Thermal Processing Control )
Working Medium
Compressed Air or Nitrogen
Voltage
380/400/415/440/600 VAC
Transport Package
Standard Package
Specification
SN-CGF0510
Trademark
SINOMAC or OEM
Origin
Changzhou, Jiangsu, China
Production Capacity
200 Sets/Year

Packaging & Delivery

Package Size
400.00cm * 200.00cm * 220.00cm
Package Gross Weight
5000.000kg

Product Description

Applications of SINOMAC Composite Autoclave

The composite autoclave is a key equipment for hot-pressing shaping of carbon fibers and resin matrix composites. The quality of the product is obtained inside the autoclave reaching an increase of mechanical features up to 20-30% compared to other methods of polymerization. The reliability and the precision of the cycles which can be obtained with our autoclaves, allowing to reach and keep high quality standards of the product, which is widely used in the high-tech fields such as aerospace, automobile, electronics, weapon, traffic, sports equipment and new type of energy, etc.

500X1000mm Small Composite Autoclave for Laboratory Use


TPC (Thermal Processing Control) Software

SINOMAC composite autoclave is equipped with advanced Thermal Processing Control (TPC) system. TPC is a PC-based control solution designed specifically for composite curing in autoclaves. It is developed on the basis of the advanced control systems that come from excellent domestic and overseas manufacturers. It is preferred control system for the most customers. The system has the login of user permissions, parts sensor selection, curing process curve setting, calling, saving and printing, automatic and manual operation, real-time data monitoring, recording, storage and printing, system status monitoring, event alarm, quality analysis,etc.

500X1000mm Small Composite Autoclave for Laboratory Use


Technical Advantages Of SINOMAC Composite Autoclave

1. No annular duct
Conventional autoclaves have an annular duct that is used to transfer air from the rear of the autoclave to the front. This air duct requires a larger pressure vessel and increase some extra ducting sheet metal .These factors will cause the high energy consumption on heating and cooling, increasing the use cost of customer's. SINOMAC composite autoclave does not require an annular air-duct and instead utilizes the floor as the forward air delivery system. It has a Sieve-Ventilation slots system in the rear and front of the autoclave. This unique design feature reduces the pressure vessel diameter by 100-150mm when compared to a conventional autoclave. This reduction in size and the elimination of the inner air duct reduces operating heating costs, pressurization costs, and equipment price.

2. Unique heating and cooling systems under the floor
In conventional autoclaves, the heater and cooling exchanger typically mounted at the rear of the autoclave. This rear-mounted approach requires the autoclave pressure vessel to be up to 1.5m longer to accommodate the components and the transition ducting at least.SINOMAC composite autoclave on the other hand incorporates floor-mounted heaters and cooling exchangers and therefore eliminates the need for the additional vessel length. This feature allows the SINOMAC autoclave's vessel to be much shorter than the vessel used for a conventional autoclave. This positively impacts operational costs by reducing the amount of heating required and the amount of pressurization gas used for a standard cycle.

3. Advantage of Sieve-Ventilation slots system
SINOMAC composite autoclave utilizes Sieve-Ventilation slot panels to straighten and balance air flow in the autoclave.
Sieve-Ventilation slots are full-area, flow adjusting panels that facilitate the balancing and straightening of the air flow at the front and rear of the autoclave prior to entering/exiting the working volume. Unlike conventional autoclaves, an composite autoclave with Sieve-Ventilation slot technology has no dead-spots and therefore provide near 100% useable volume for your parts. The overall result is unequalled temperature uniformity down the entire length of the autoclave and uniform heating and cooling of your valuable part load.

4. Advanced structure of door sealing ring
Using ceramic fiber channel segregation, and a special cooling system.

5. Fully sealed circular motor fan
Fully sealed special motor, bearings with SKF high-temperature series. The structure is easy to maintenance and, no oil leakage, no air leakage.

500X1000mm Small Composite Autoclave for Laboratory Use


Specification
 
MODEL# SN-CGF0510 COMPOSITE AUTOCLAVE_TECHNICAL PARAMETER
No. Description Unit Specifications and Parameters
1 Effective Working Diameter mm 500
2 Effective Working Length mm 1000
3 Autoclave Track Distance mm No track
4 Track Height (from floor to track plane) mm No track
5 Design Pressure Mpa 1.2
6 Max. Working Pressure Mpa 1.05
7 Max. Pressurization Rate (average) bar/min 0.6
8 Max. Depressurization Rate (average) bar/min 0.6
9 Safety Valve Exhaust Mpa 1.15
10 Design Temperature ºC 250
11 Max. Working Temperature ºC 230
12 Max. Heating Rate(Air average) ºC/min 3
13 Max. Cooling Rate (Air average) ºC/min 3
14 Thermal Load during Test Kg 20KG steel
15 Temperature Uniformity at Steady State ºC ±2
16 External Shell Temperature at max. Temperature ºC <60
17 Quick Openning Door Mode --- hydraulic
18 Working Medium --- Compressed Air
19 Heating Mode --- Electric (Convection+Radiation)
20 Heater --- Inconel Tubular Heaters
21 Heating Power KW 25
22 Quantity of Circulating Fan Motor Set 1
23 Power of Circulating Fan Motor KW 7.5
24 Thermocouple Type --- Type K or J  
25 Air Temperature Thermocouples Piece 1
26 Part Temperature Thermocouples Piece 4
27 Quantity of Pressure Transducer Piece 1
28 Vaccum Lines Piece 2
29 Quantity of Vacuum Probe Piece 2
30 PLC-controlled  Valves on each Vacuum Line --- Vacuum and Vent
31 Min. Vacuum Pressure Mpa -0.08
32 Standard Control Mode --- PLC+PC
33 Control Software --- Thermal Processing Control (TPC)
34 Insulation Type --- Internal
35 Insulation Material mm Ceramic fiber
36 Insulation Thickness --- 80
37 Insulation Sheet Metal ºC Stainless Steel or Aluminized  Steel
38 Working  Environment Temperature --- Min. -20ºC, max. +45ºC
39 Working  Environment Humidity --- <60%
40 Power Supply --- 220/380VAC, 3P+N+PE, 50/60Hz
41 Weight Kg 1760

Professional Workshop

500X1000mm Small Composite Autoclave for Laboratory Use

From the SINOMAC Team, with 15 years of experience.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now